DNA Engine®
Peltier Thermal Cycler (PTC-200)

DNA Engine featuring Dual Alpha™ unit with 96-well and Moto Alpha™ alongside.

The DNA Engine instrument is the cycler that revolutionized thermal cycling.   Unprecedented thermal uniformity and swappable blocks ensure consistent results, experiment-to-experiment and block-to-block.   This rugged machine is more than just a cycler, it's a platform for new features and upgrades as research needs evolve.

Features of the DNA Engine thermal cycler
 
Single-bay cycler accommodates over ten different Alpha™ sample blocks, including independently controlled dual blocks.
 
Temperature Gradient capability employs dynamic ramping, guaranteeing consistent hold times across all sample wells.
 
Upgradable to real-time fluorescence detection with the purchase of an Opticon™ or Opticon 2 retrofit.
 
 
Advantages of all DNA Engine® systems:
 
Sample Blocks  

Swappable Alpha unit sample blocks are designed for frequent change; they can be swapped in seconds; they seat many types of reaction vessels.
 
Independently controlled dual blocks are available for running two different protocols simultaneously.
 
Gradient Capability is standard on all DNA Engine systems when fitted with 96-well Alpha units.
 
Unique Peltier heat pumps are built by MJ Research specifically for cycling.   Years of experience and proprietary technologies make MJ modules last longer than any other.
 
Multi-zone feedback control utilizes multiple sensors combined with four “zones” for heating and/or cooling to optimize thermal profiles every 50 milliseconds.

Performance

Extraordinary temperature uniformity of ±0.4°C within 30 seconds of arrival at 90°C (well-to-well) average, all Alphas).
 
Superb thermal accuracy of blocks within ±0.3°C of NIST standard at 90°C (average across block, all Alphas).
 
Thermal range of -5° to 105°C
 
Rapid ramp rates of up to 3.0°C/sec

Operation

Two thermal control options block control or calculated control.
 
Choice of two heated-lid designs accommodate many vessel types and various sealing options, allowing maximum flexibility in experimental designs.   Heated lid temperatures can be set with any DNA Engine instrument.
 

Manual Hot Bonnet® heated lid with a unique thumbwheel for adjusting height and pressure
Moto Alpha™ units can be remotely commanded to open, close, and adjust height and pressure.   Alternatively it may be opened and closed with the touch of a button.
 

The DNA Engine Instrument

Available Products:
PTC-0200 DNA Engine Thermal Cycler Chassis
(does not include the Alpha unit?requires 1)
Available Alpha Units (Block/Heat-pump Assemblies):
ALS-1260 Holds 60x0.5ml tubes
ALS-1296 Holds 96x0.2ml tubes or one 96-well plate
ALS-1238 Holds one 384-well plate
ALS-1200 Flat Block™ for microarrays, biochips, flat-bottom vessels
ALD-1233 Dual block holds 2x30x0.5ml tubes
ALD-1244 Dual block holds 2x48x0.2ml tubes or half-plates
ALD-1234 Dual block holds 30x0.5ml and 48x0.2ml tubes
ALD-0211 Dual block holds 2x16 glass slides
ALP-2296 Moto Alpha Holds one 96-well plate and has motorized Power Bonnet lid
ALP-2238 Moto Alpha Holds one 384-well plate and has motorized Power Bonnet lid
ALP-2200 Moto Alpha Flat Block for microarrays, biochips, flat-bottom vessels and has motorized Power Bonnet lid

 