          | DNA Engine® Peltier Thermal Cycler (PTC-200)
 
           DNA Engine featuring Dual Alpha™ unit with 96-well 
          and Moto Alpha™ alongside.  The DNA Engine instrument is the cycler that revolutionized thermal 
          cycling.   Unprecedented thermal uniformity and swappable blocks 
          ensure consistent results, experiment-to-experiment and 
          block-to-block.   This rugged machine is more than just a cycler, it's 
          a platform for new features and upgrades as research needs evolve.  
            
              |  |  
              |  |  
              | Features of the DNA Engine thermal cycler 
 Single-bay cycler accommodates over ten different
              Alpha™ sample blocks, including 
              independently controlled dual blocks.
 
 Temperature Gradient 
              capability employs dynamic ramping, guaranteeing consistent hold 
              times across all sample wells.
 
 Upgradable to real-time fluorescence detection with the 
              purchase of an Opticon™ or
              Opticon 2 retrofit.
 
 |  
              |  |  
              | Advantages of all DNA Engine® 
              systems: 
 Sample Blocks
 
                Swappable Alpha unit sample blocks are designed for 
                frequent change; they can be swapped in seconds; they seat many 
                types of reaction vessels.
 Independently controlled dual blocks are available for 
                running two different protocols simultaneously.
 
 Gradient Capability is 
                standard on all DNA Engine systems when fitted with 96-well 
                Alpha units.
 
 Unique Peltier heat pumps are built by MJ Research 
                specifically for cycling.   Years of experience and proprietary 
                technologies make MJ modules last longer than any other.
 
 Multi-zone feedback control 
                utilizes multiple sensors combined with four “zones” for heating 
                and/or cooling to optimize thermal profiles every 50 
                milliseconds.
 Performance  
                Extraordinary temperature uniformity of ±0.4°C within 
                30 seconds of arrival at 90°C (well-to-well) average, all 
                Alphas).
 Superb thermal accuracy of blocks within ±0.3°C of NIST 
                standard at 90°C (average across block, all Alphas).
 
 Thermal range of -5° to 105°C
 
 Rapid ramp rates of up to 3.0°C/sec
 Operation  
                Two thermal control options block control or 
                calculated control.
 Choice of two heated-lid designs accommodate many vessel 
                types and various sealing options, allowing maximum flexibility 
                in experimental designs.   Heated lid temperatures can be set 
                with any DNA Engine instrument.
 
 
                  Manual Hot Bonnet® heated lid with a 
                  unique thumbwheel for adjusting height and pressureMoto Alpha™ units can be remotely commanded to open, 
                  close, and adjust height and pressure.   Alternatively it may 
                  be opened and closed with the touch of a button.
 
 |  
              | 
                
                  | 
                  The DNA 
                  Engine Instrument |  
                  | Available Products: |  
                  | PTC-0200 | DNA Engine Thermal Cycler Chassis (does not include the Alpha unit?requires 1)
 |  
                  | Available Alpha Units (Block/Heat-pump Assemblies): |  
                  | ALS-1260 | Holds 60x0.5ml tubes |  
                  | ALS-1296 | Holds 96x0.2ml tubes or one 96-well plate |  
                  | ALS-1238 | Holds one 384-well plate |  
                  | ALS-1200 | Flat Block™ for microarrays, biochips, 
                  flat-bottom vessels |  
                  | ALD-1233 | Dual block holds 2x30x0.5ml tubes |  
                  | ALD-1244 | Dual block holds 2x48x0.2ml tubes or 
                  half-plates |  
                  | ALD-1234 | Dual block holds 30x0.5ml and 48x0.2ml tubes |  
                  | ALD-0211 | Dual block holds 2x16 glass slides |  
                  | ALP-2296 | Moto Alpha Holds one 96-well plate and has 
                  motorized Power Bonnet lid |  
                  | ALP-2238 | Moto Alpha Holds one 384-well plate and has 
                  motorized Power Bonnet lid |  
                  | ALP-2200 | Moto Alpha Flat Block for microarrays, 
                  biochips, flat-bottom vessels and has motorized Power Bonnet 
                  lid |  |    |  |  |  
 
        
        
          
            | 
                
                
                  | ****SPECIAL 
                  PROMOTION****   |  |  
 
 
        
        
          
            | 
                
                
                  | 
                  NEW!!!! ONLINE ORDERING for 
                  select items  
                  For terms and conditions please 
                  see PAYPAL   
                  Please 
                  CONTACT US for quotes on all other items. 
                  All orders must be prepaid. 
                  Credit card is accepted. |  |  
 
 
 |